Tosseh Tajhizat Pezeshki Iranian (TTPI) Co.

  • +98(21)88510062
  • Contact Us
  • فارسی
  • Home Page
  • About Us
  • Products
  • Contact Us
Search
  • Persian

TTPI Logo

Menu
Click to enlarge
Home Gastroenterology Esophageal Flexella Plus
Esophageal Danis Seal stent
Back to products
Esophageal HV Plus
ELLA-CS

Esophageal Flexella Plus

  • Unique delivery system
  • Removable esophageal stent
  • Anti-migration and atraumatic design
  • Excellent flexibility
  • Acid-resistant retrieval loop
  • Atraumatic stent retrieval
Category: Gastroenterology
Share:
  • Description
  • Additional information
  • Reviews (0)
  • About brand
Description

SX-ELLA Stent Esophageal - FLEXELLA PLUS

Basic Description

  • SX-ELLA Esophageal stent FLEXELLA PLUS is designed to relieve malignant esophageal strictures in all parts of the esophagus with respect to necessary 2-cm distance from the upper esophageal sphincter.
  • If the stent is deployed across the gastroesophageal junction, it should be equipped with an anti-reflux valve to prevent reflux of gastric juice.
  • Implantation of the stent should be performed under fluoroscopic guidance.
  • The FLEXELLA PLUS is routinely distributed in a delivery system with distal release mechanism. The stent is deployed by pulling the sheath (PULL SYSTEM). As an alternative, we offer also delivery system with proximal stent release (PUSH SYSTEM) in which the stent is deployed by pushing the shaft.

Indications

  • Flexella Plus is designed for relieving malignant or benign esophageal strictures if standard operation is contraindicated. It can be used for treatment of esophagorespiratory fistulas as well.

Contraindications

  • Malignant or benign strictures in the upper part of esophagus too close to the cricopharyngeal muscle

Relative Contraindications

  • Use of the valved stent shall be carefully considered in patients after partial gastrectomy which produced small, horizontally lying gastric remnant. Distal end of migrated stent might impact into the gastric wall and consequently close the valve.

Additional Description

  • Esophageal stent FLEXELLA PLUS (fig. 1) is braided of a wire made of nickel-titanium alloy – nitinol. This material has unrivaled flexibility, shape memory and durability.
  • The stent is hand braided therefore the ends are non-traumatic.
  • The radiopacity of the stent is secured by markers, made of platinum-iridium alloy, that are fixed to a stent mesh.
  • The covering of the stent is made of durable silicone. The construction of the stent FLEXELLA PLUS and the material used guarantee a sufficient expansion force.
  • The shape of the FLEXELLA PLUS decreases the risk of stent migration.
  • If the stent is to be implanted into the lower part of the esophagus, it may be optionally equipped with an anti-reflux valve.
  • The delivery system of the stent FLEXELLA PLUS is equipped with a special splittable olive (fig. 2). This part of the delivery system splits off during the stent placement. This unique feature allows smooth and easy delivery system removal.
  • Stent is also available in delivery system with proximal release (fig. 3) that is suitable for strictures in the upper part of the esophagus, where the exact location of the upper edge of the stent is required.
  • It is recommended to dilate the esophageal stricture to the minimum diameter of 10 mm.

Miscellaneous Important Facts

  • A physician to implant the stent FLEXELLA PLUS shall be skilled appropriately.
  • Stent shall be introduced by using the ultra stiff guide wire only.
  • Stent implantation should be performed under fluoroscopic and/or endoscopic control.
  • Proximal end of the stent shall be placed out of the tumorous stricture, i.e. in a healthy tissue.
  • Instructions describing correction of stent misplacement/partial migration or its removal from the stomach after full migration shall be strictly followed. Changing the stent position after the period longer than 5 days since the date of implantation shall be well-considered because a part of the stent may be incorporated into the esophageal mucosal tissue at that time.
  • The patient shall eat semi-solid food and drink plenty of liquids after implantation.

Once even a small portion of the stent is released from the delivery system, it is strictly prohibited to push the delivery system forward to prevent stent damage and potential patient injury.

For more information about this product, check its catalog or contact our experts.

Download Catalog

پیوست‌ها

File Description File size
pdf flexella_catalog 1 MB
Additional information
برند

ELLA-CS

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Esophageal Flexella Plus” Cancel reply

Your email address will not be published. Required fields are marked *

About brand

Introduction of ELLA-CS Company

ELLA- CS s.r.o

ELLA-CS is a purely domestic company, without any foreign ownership, yet its production is represented in more than 70 countries over the world and the distribution network is still growing.

Research, development, professionality

The success of ELLA-CS products indicates reliability and exceptional quality of manufacture. The company works steadily on research and development of original health care devices to widen therapeutic options for practitioners. Cooperation with leading specialists and practitioners is extremely valuable for successful research led by our company. So our products are submitted to rigorous examination in scientific publications and studies by renowned researchers from all over the world. The main intention of the company is to continue developing original products in close cooperation with the most important clinical centers of the world.

Recent production

Recently the company has mainly focused on the gastrointestinal stent production. Our portfolio includes esophageal, pyloroduodenal, biliary and colorectal stents. Our company is sole manufacturer of several globally unique health care devices.

ELLA-CS is an exclusive producer of the following health care devices:

Biodegradable stent: This stent is successfully used in treatment of esophageal, tracheal, biliary and intestinal illness, in the colon the biodegradable stent has been successfully used to treat the Crohn’s disease.

Danis stent: Danis stent is a unique health care device developed for stopping of acute variceal bleeding. By developing and manufacturing of this product the company ELLA-CS brought a revolutionary solution for treatment of this critical condition. This way of treatment can be used in emergency situation, brings better comfort to the patient and allows medical staff to perform further treatment more easily.

Extractor: Extractor is an original device for removing of esophageal stents if necessary. The Extractor design allows removal of nitinol esophageal stents manufactured by ELLA-CS without causing trauma to the esophageal wall.

Custom manufacturing: For selected patients our company manufactures customized devices. The production is based on the medical practitioner’s written prescription. Frequently stents of non-standard dimensions are requested.  Up to that our company is also competent to produce most complicated implants as bone replacements for cranioplasty, implants for reconstruction of large bone defects, implants for maxilo-facial surgery, plastic surgery, etc.

History of health care devices production

In the past period the company portfolio included products like peripheral non-vascular and vascular stents, prostatic spirals, implantable ports, ophthalmic implants, aortic stentgrafts and other standard products or custom-made devices. Some of these are still produced for our customers.

The quality management system

The company established and maintains the quality management system in compliance with EN ISO 13485. It operates clean room facilities with equipment ensuring the air cleanliness classified by EN ISO 14644 as ISO Class 7. The manufacture meets all principles of good practice as they are established by international, European and Czech standards.

History

  • 2007: The transformation of the company from a physical person to a legal entity with the name ELLA-CS, s.r.o. Since 2007 is ELLA-CS under the supervision of the Notified Body EZU Praha (NB 1014) in accordance with European legislation and Council Directive 93/42/EEC concerning medical devices. CE mark for esophageal BD stent was approved
  • 2005: CE mark for Danis stent was approved.
  • 2000: The company received the first CE Certificate.
  • 1996: The audit (TÜV) for obtaining ISO 9001, EN 46001 was successfully completed.
  • 1991: ELLA-CS was established concentrating on the production of specialized medical equipment. ELLA-CS came into existence as a logical continuation of production activity dating back to 1986.
  • 1986: Institute of Experimental Oncology of the Medical Faculty of Charles University in Hradec Králové developed research in the field of special health care devices. In this year the first thermocouple probes for radiotherapy were developed in this institute.

Related products

Enterella Colorectal

Gastroenterology
  • Easy deployment
  • Excellent flexibility
  • Atraumatic stent ends
  • Smooth alignment around flexures
Quick view

Extractor

Gastroenterology
  • Simple and reliable removal system
  • Atraumatic stent retrival
  • Allows removal of migrated stents from stomach
  • Radiopaque markers
Quick view

Esophageal Degradable

Gastroenterology
 
  • Stent system for treatment of benign esophageal strictures.
  • Biodegradation
  • Excellent flexibility
  • Radiopaque markers
  • Splittable olive tip
Quick view

Nitinella Plus

Gastroenterology
  • Excellent flexibility
  • Atraumatic stent ends
  • Reconstrainability
  • Radiopaque markers
  • Optional covering
Quick view

Esophageal Danis stent

Gastroenterology
  • Removable stent for treatment of bleeding from esophageal varices
  • Easy implantation without the need for endoscopy / X-Ray control
  • Secure hemostasis through direct compression of varices
  • Oral intake maintained from time of implantation
Quick view

Esophageal Danis Seal stent

Gastroenterology
  • Removable stent for treatment of esophageal leaks and ruptures
  • Large diameter with optimum length and expansion force
  • Durable silicone covering
  • Special anti-migration design
Quick view

Pyloroduodenal ENTERELLA

Gastroenterology
  • Easy deployment
  • Excellent flexibility
  • Atraumatic stent ends
  • Smooth alignment around flexures
Quick view

Esophageal HV Plus

Gastroenterology
  •  Unique delivery system
  • Removable esophageal stent
  • Special anti-migration design
  • Excellent flexibility
  • Acid-resistant retrieval loop
  • Atraumatic stent retrival
Quick view

Tosseh Tajhizat Pezeshki Iranian (TTPI) Co.

  • Unit 28,No 24,10th Alley,Qaem Maqam-e-Farahani St.Tehran
  • (+98)-21-88510062-5
  • info@ttpimed.com
  • Easy Access
    • Products
    • Contact Us
    • Blogs
  • Customer Access
    • About Us
    • Educational Videos
  • Links
    • Ella-Cs website
    • Endo Access website

© - All Right Reserved for TTPIMED Company.
(Designed and Developed by Smart Design)

  • Menu
  • Categories
  • Gastroenterology
  • Endoscopic Instruments
  • Home Page
  • About Us
  • Products
  • Contact Us
Start typing to see posts you are looking for.